Complete enforcement of specifications for issue of construction permit
and as per new Anti |
 |
 |
 |
 |
| - Earthquake Reinforced
Concrete Regulation as announced in Government newspaper. 2184B / 20 - 12
- 99, enforced by Ministerial Decision: Ä 17a/141/3/Ö.Í. 275 (Å.Á.Ê. 2000) |
 |
 |
 |
 |
 |
 |
 |
|
 |
General
excavation and foundation to the appropriate depth depending on whether
a basement exists or not and until stable ground is achieved. The surface
of the excavation will be graded with concrete to allow for better setting
of foundation and prevent oxidation of reinforced steel used. Casting and
construction of foundation with high quality reinforced concrete as per
the static specifications and enforcement of the Regulation of Concrete
Technology (1997) ensuring excellent concrete performance. |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
 |
All
of the above are first wood formed and then reinforced with steel according
to specifications. They are then covered with high quality concrete and
exterior surfaces of reinforced concrete are covered with an insulating
material, wherever required, for excellent heat insulation of building.
|
 |
 |
|
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
 |
 |
Exterior
walls are composed of double brick skin cavity with an insulation filling
and the construction of two reinforced cement rings, one at the height of
the window sills and one at the window and door headers for better performance
of building. Interior walls are constructed with a single brick skin and
with two reinforced cement rings at the same height as the exterior walls.
|
 |
| Constructing your house in
crete |
 |
 |
 |
| |
 |
|
 |
 |
 |
 |
|
 |
Constructed with Swedish
timber. Thickness according to static specifications of the supporting wood.
It is internally lined with Swedish timber and varnished or painted with
oil paints, having the capability to use colours of your choice. Externally
the roof is lined with a tar film for water - proofing and a heat insulating
material is applied. The ceramic roof tiles are then placed.
|
 |
 |
 |
|
 |
 |
 |
 |
|
 |
The electrical
connection is achieved through a current gauge, which is placed outside
the house, by the power supply company, leading to the main distribution
/ fuse box located inside the house and to all rooms through the wiring
in the walls. All wiring can be monitored through shunt boxes at various
points. The wiring leads from the distribution / fuse box to the different
lighting points, switches, sockets etc. Each room includes a full installation
of lighting points, switches, sockets, TV and telephone points. The main
fuse board is equipped with a safety circuit breaker and individual fuses
for the water pump, stove etc. Light fittings and their installation are
the customer's responsibility. |
 |
| |
 |
|
 |
 |
 |
 |
|
 |
Underground plumbing
via a water metre, placed by the municipality, leading from boundary of
property towards distribution box located inside the dwelling. Inside the
house the installation course is beneath the flooring, inside spiral conduits
in case replacement of a water pipe becomes necessary, which end up at the
different points - kitchen, lavatories, exterior taps etc.
Through a back up water tank whose capacity is 1 ton and a water pump which
functions when network water pressure isn't adequate, the dwelling has a
back up water supply even when there is a municipality water shortage. All
sanitary articles for lavatories as well as accessories, hot - cold water
taps including tap for kitchen sink and connections for washing machine
or dishwasher if requested, as an extra by the customer, are all included
in the installation. The dwelling's waste connection leads to drainage network,
where existent, or to an absorbent septic tank. |
 |
| |
 |
|
 |
 |
 |
 |
|
 |
Inner and outer walls
are plastered, as shown in views, in three coats. One of splashed plaster
for better adhesion of material on surface. The second, a rough coat and
the final coat, a thinner, fine layer of plaster for a smooth surface. On
outer walls a net is placed between main construction and brick walls for
the better bonding of the plaster. |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
Level ceilings consist
of reinforced concrete, internally plastered and painted with high quality
paint. Externally the surface is cleaned and then covered with a tarmac
liquid. Then a tar film is placed, by using a flame-thrower, for excellent
water resistance. Finally, the surface is covered with a heat insulating
material and then the insulation is entirely covered with resistant cement
mix. |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
Outer and inner floors, verandahs
and staircases are tiled. A great selection of tiles is available. At points
where tiles change (e.g. doors etc), marble is placed. |
 |
 |
 |
|
 |
 |
 |
 |
|
 |
All internal doors have a wooden frame and are
lined with MDf, in a wide selection of colours and styles. All external
doors, windows and shutters are composed of Swedish timber or white aluminium
(the frame of the shutters is aluminium, the other parts are plastic)
and include doorknobs or handles, accessories and window or door panes.
On the main entrance door a new safety cylinder is placed upon completion
of construction. Bedroom wardrobes, whether or not they are built-in,
depending on specifications, include drawers, shelves and hanging rails.
The frame is made of melamine and the doors of MDF, either in the colour
of wood or in any other colour from our selection.
|
 |
| |
 |
|
 |
 |
 |
 |
|
 |
The cupboards are installed on the floor and
on the wall, according to the plans, and include worktops, a double sink
with a drainer, a hot - cold water tap, a kitchen exhaust fan etc. All
cupboard frames are made of melamine and the doors are MDF in the colour
of wood or any other colour of your choice. Walls between worktops and
upper cupboards are tiled with your choice of tiles. Electrical appliances
(e.g. stove, fridge etc.) are not included.
|
 |
| |
 |
|
 |
 |
 |
 |
 |
|
 |
External
walls are painted with the highest quality paint. Internal walls and ceiling
are painted with paint for interior surfaces in a selection of colours.
Sloping roofs, doors, windows, shutters etc. are varnished or painted with
a colour of your choice. Windowsills in marble or local stone, which is
sanded and polished with stone varnish. Exterior work, such as lighting
points ready for installation of light fittings, water and airtight sockets
and taps on verandahs will be completed. Driveway and parking spaces are
gravelled. |
 |
 |
 |
|
Upon delivery the building is cleaned and all abeyance
concerning the Greek Social Security Association and the Minimum Construction
Cost will have been settled for the granting of the final power supply
of the house.
Some of the articles at an extra cost are:
 |
| 1. fireplace and chimney |
| 2. a stone arch |
| - Central Heating : Full installation or only
provision pipes |
| - air conditioning, domestic appliances etc. |
| - timber or marble floors |
| - storage lofts |
| - texture plastering |
| |
3. solar panel
4 . stone pillars
5 . swimming pools or only provision pipes
6 . stone building walls
7 . stone wall around boundaries
8 . entrance gate (different types)
9 . wooden pergola
10 . satellite TV
11 . stone edging
- basements
- barbecues
- textured plastering
- exterior doors or windows in aluminium colours
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|